Turned it off, and when I tried to turn it back on the motor couldnt get the belt moving.So, couple of questions:1) Does anyone have the old service manual for this girl? will my air compressor take off lug nuts? Ive added a photo of the Coleman Powermate CL0504013 for folks to see what were talking about. However, if the air becomes too hot for the compressor to handle, something is indeed wrong with the machineTime stamps:0:00 How to prevent an air compressor from overheating2:02 Causes of Air compressor to Overheat1:25 Low Suction Pressure2:50 Faulty Metering Devices3:07 Excess Discharge Pressure3:56 Inadequate Cooler Space4:34 Inadequate Room for Compressor to Properly Vent5:15 Compressor Parts are old or Clogged5:55 Frequency of Use6:32 Ambient temperature7:02 Eroded Oil8:07 Thermal Valve8:50 Type of Air Compressor#Compressor #Overheating#P\u0026HS04Playlist of Pneumatic and Hydraulic Systems:https://www.youtube.com/playlist?listOther Videos:Pneumatic Systems | Introduction | Pneumatic machines | Applications | Features:https://www.youtube.com/watch?v=S_WJ-Components of a Pneumatic System/ Five most common Elements of a Pneumatic Machinehttps://youtu.be/2AhFJoxuk6ETypes of Air Compressors | Reciprocating, Compound, Rotary Screw, Rotary Vane, Scroll, turbo, etchttps://youtu.be/v6K3kIP1aH4Share this videohttps://youtu.be/qPvvwbxg3yw Improve ventilation or relocate compressor. So then I had to fill in the upper and lower part of the frame support that the cooler did not cover I used some old fish tank light top filler cover cut to fit. ABAC ABC7-2180V 7.5 HP 208-230 Volt Single Phase Two Stage Cast Iron 80 Gallon Air Compressor ABAC Air Compressors cast iron air compressors feature low RPM, heavy duty cast iron pumps. AboutPressCopyrightContact. Same problem of blowing fuses in disconnect switch. Air in tank, low pressure line connected, high pressure line connected-> motor will start and run. i need a solution how to unlock the regulator knob back to its position as it says on the knob to push to lock so i tried to pull to unlock but with no luck, i didnt even use my air compressor yet i was figuring out how to use it and i accidentally locked it, Im not sure if working with it while locked is ok i dont want to do another mistake, i attached 2 videos 1 explaining my knob how i cannot move the black knob separately from the red ring and the second video explains how it was before locking. What parts do I need for this modification and is it advantageous to use a 3/8 pressure regulator. Air compressors sometimes have duty cycles. Here are a few more air compressor problems and some things to try on your own to fix them: Oil in reservoir has a milky appearance: air intake needs to be less humid to reduce air in the oil. In other words, the back-pressure exceeds the ability of the motor to overcome the problem, and the motor struggles, or, the motor itself is failing and hasnt the ability to develop enough force to overcome load. I got it non working for a deal but have never gotten it to work. Do you have any recommendations on what the trouble is and how I could address them? Are you using this compressor for business.. perhaps for painting? Limit air usage to compressor capacity by using fewer or smaller tools. The gas is then pushed out of the cylinder to the next stage of compression or to the discharge connection. Anytime. Ill give that idea a try. It has a pressure release valve in each head where some higher end pumps would have unloaders (I believe). Anything new about the power supply to the compressor? I have 1.7 hp,33gal it will fill up one time and will not start for 3hours . It appears to say F J10 078, The pump is a 2 stage inline pump (not a V). There doesnt seem to be any info online about the fittings, sizes etc, and definitely no spares or replacements. Air in tank, high pressure line connected, low pressure line disconnected-> motor will start, strain, and then stop, 4. Ive soaped every fitting, tightened those which were leaking. Start by loosening them and see if the top will lift. As to how to plumb the pressure switch, depends on what type. Check for leaks or restriction in hose or piping. 3/8 Npt to 1/2inch coupler H style industrial (these are the highest flow of the Industrial) by Milton. Adding a larger regulator shouldnt be an issue. I need to know the positions these need to be in. 4. It sits recessed in the wheel housing. does my compressor need a new pressure switch? What switch are you planning to use? Im technologically inept, I guess. Check to make sure that fuses are of proper ampere rating. Heres where you can find the answer or post your own question about that brand if no answer if desired! Are you sure that the operating pressure of the line to the gun does not exceed the adhesive gun operating pressure? Shamma, only one of the uploads has a video. Air leaking from inter stage safety relief valve when compressor is pumping. I have it all on 1/2off the compressor 120psi to cabinet, and at the cabinet reg turned down to 40psi and water trap in to cabinet. To continue visiting our website, please choose one of the following supported browsers. What would be the symptoms? I have changed the oil and cleaned the air filter. { Print. We have replaced the guns completely and adjusted the needle settings. Even though a lot of manuals are already available the page is updated constantly, check this page for new documents every now and then. Im no expert on glue guns. I have a 220v 500a60 Sanborn compressor that I am having some issues with. Using it with high speed carving tool, Vortex F5. The Pro User's ATF-S Piston range has been designed with ease of use in mind. You are now on the rotary screw compressor page, but there's also the reciprocating (piston) compressor page and the portable (diesel) compressor page. Is the motor starting to die? I think its time to return the compressor for a new one, return the regulator for a replacement (which they likely wont do as it was part of the compressor) or since these regulators sell for under $20 new, at a decent hardware or big box store that sells tools you might need to acquire a new one. I have contacted Lowes and Kobalt and neither can help only refer me back to the other. Please use the search box or the pages with links to locate and read them. Stay oil-free. Im sure it needs new oil, etc.2) Do you think the bogging down is being caused by the belt tension? Page 31 And it will work with the M style industrial too.I all so use this V style coupler for the spare tank hookup when needed. That was a great suggestion to junction all the ball valve drops at the after cooler manifold and add an auto drain.. Parts have been order to install auto drains. Are you unable to find ? Granted, cool, dry compressed air is better for downstream applications, but after-coolers are themselves expensive, and use expensive energy typically. The correct maintenance is paramount to this perspective. Would like to add a filter too. Most pages have a comment section where you can leave a question about that specific make of compressor. Sometimes it cruds up and prevents air from getting into the tank. On start up it runs for a few seconds and trips the thermal overload. $ 119 Compressed Air Basics. I took your suggestion and purchased a water-trap to replace the water-trap regulator combo I originally installed at the air compressor tank. Sealey Air Compressor Troubleshooting - YouTube 0:00 / 15:11 Sealey Air Compressor Troubleshooting Sealey Tools 9.79K subscribers Subscribe 627 Share 123K views 5 years ago #AirCompressor. Not using an extension cord, I hope? Always use ORIGINAL PART as replacement spare parts to ensure long life . When performance issues arise with an air compressor, the problem can often be traced to heating issues. Specs to comply need to be 1 horsepower, meet rate of 3 scfm @ 40 psi. Abac A29B 90 CM3 . My hausen cambell compressor has 2 tanks when air presure drop to a certain level the motor want kick back on. Ive added a photo of what I believe is your compressor so folks can see what were talking about. Get creative with how you plumb if needed as the air (by and large) doesnt care the path to the discharge coupler, as long as there are as few air flow restrictions as possible. This is as far as I have gotten as I cant seem to find anybody in the UK the will service it. tested at 200PSI and 1/2NPT fittings no hardware included. Question Title: ABAC compressor fault; Asked by: Guest; Asked On: 16-08-2015 01:33; Hi I am desperately looking for help. http://fix-my-compressor.com/when-an-air-compressor-runs-and-runs/, https://www.clarkeinternational.com/pages/clarke-service-support, Air Coming Out the Intake Filter on Air Compressor? Quote:except that it will drain the tank faster and cause more rapid cycling of the compressor motor and pump. One at the bottom of the compressor tank, and another for the aftercooler manifold. By putting in a inline check valve around the cooler it trap the compressed air at the cooler, making the line all most the same length as the factory one from the head to the tank. ABAC Catalogue 2021: all the compressors, tools and accessories your business needs. And if you have a tip for another compressor user? Are you saying that the hose burst, not at the clamps but mid-hose, before the compressor reached the normal cut out pressure, and the hose is rated for 300 PSI? I then turned off the motor, drained the tank to 80 PSI. Should I take out the top of the tank check valve or can I just leave it in the system? I then removed the unloader tube and again the motor was able to turn on. Pump stops for second, motor stops turning more info please? What am I doing wrong??? I saw a modification where someone had this same compressor and changed the regulator to an 80cfm @100psi. They said nothing was wrong with the motor. If you have the old one, and even if you dont, when times permit, take it to a good, industrial plumbing supply house. Check for bent. course online . Choose Options Compare. Something I cant find any help on is the delivery tube between the compressor pump and the check valve. I have changed the electric motor. Knock occurs while compressor is loading. Would the exact motor need to be installed or are there options? I wouldnt if this were me. 4. Please check that out and advise. An overheated air compressor is the result of internal factors, external conditions or sometimes both. Join one of my courses on compressed air and air compressors. Service unit (change oil, clean or replace air cleaner element, more often, at least every 45 days or 500 operating hours for oil changes. The GENESIS compressor is ideal for OEMs and the medium size industrial and assembly aplications. Terence, is it taking much longer to fill up to the cut out pressure than normal? I have a Porter Cable 24 Gallon from Tractor Supply.